{"id":1129,"date":"2026-04-24T06:48:35","date_gmt":"2026-04-24T06:48:35","guid":{"rendered":"https:\/\/rtooxidizer.com\/?post_type=product&#038;p=1129"},"modified":"2026-04-27T08:48:27","modified_gmt":"2026-04-27T08:48:27","slug":"high-salinity-waste-liquid-boiler","status":"publish","type":"product","link":"https:\/\/rtooxidizer.com\/nl\/product\/high-salinity-waste-liquid-boiler\/","title":{"rendered":"High-Salinity Waste Liquid Boiler"},"content":{"rendered":"<div style=\"display: flex; flex-wrap: wrap; gap: 16px; margin: 0 0 36px 0;\">\n<div style=\"flex: 1 1 180px; background: #EEF5FC; border-left: 4px solid #1B6AA8; padding: 18px 20px; border-radius: 6px;\">\n<div style=\"font-size: 26px; font-weight: 800; color: #0a3a6b; line-height: 1;\">0.5\u201320 t\/h<\/div>\n<div style=\"font-size: 13px; color: #4a5a6a; margin-top: 6px;\">Waste Liquid Feed Rate<\/div>\n<\/div>\n<div style=\"flex: 1 1 180px; background: #EEF5FC; border-left: 4px solid #1B6AA8; padding: 18px 20px; border-radius: 6px;\">\n<div style=\"font-size: 26px; font-weight: 800; color: #0a3a6b; line-height: 1;\">Up to 35%<\/div>\n<div style=\"font-size: 13px; color: #4a5a6a; margin-top: 6px;\">Total Dissolved Solids (TDS)<\/div>\n<\/div>\n<div style=\"flex: 1 1 180px; background: #EEF5FC; border-left: 4px solid #1B6AA8; padding: 18px 20px; border-radius: 6px;\">\n<div style=\"font-size: 26px; font-weight: 800; color: #0a3a6b; line-height: 1;\">\u2265 99.99%<\/div>\n<div style=\"font-size: 13px; color: #4a5a6a; margin-top: 6px;\">Organic Destruction Efficiency<\/div>\n<\/div>\n<div style=\"flex: 1 1 180px; background: #EEF5FC; border-left: 4px solid #1B6AA8; padding: 18px 20px; border-radius: 6px;\">\n<div style=\"font-size: 26px; font-weight: 800; color: #0a3a6b; line-height: 1;\">ZLD-Ready<\/div>\n<div style=\"font-size: 13px; color: #4a5a6a; margin-top: 6px;\">Dry Salt Recovery Option<\/div>\n<\/div>\n<\/div>\n<p><!-- =============== OVERVIEW =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 10px 0 22px 0;\">What Is a High-Salinity Waste Liquid Incinerator?<\/h2>\n<p style=\"font-size: 16px; line-height: 1.75; color: #1a2a3a; margin: 0 0 18px 0;\">The Ever-power <strong>high-salinity waste liquid incinerator<\/strong> is an integrated furnace-boiler unit engineered for the one waste stream that breaks most water treatment plants \u2014 hot, concentrated brine that still carries organic contamination. Biological plants cannot survive the salt load; standard waste liquid incinerators foul their heat transfer surfaces within weeks. This product is purpose-built for exactly that duty.<\/p>\n<p style=\"font-size: 16px; line-height: 1.75; color: #1a2a3a; margin: 0 0 18px 0;\">The furnace oxidises organic matter at \u2265 1,000 \u00b0C, the dissolved salts melt and drop out as a dry ash or molten slag, and the remaining heat is recovered as saturated steam in a downstream convective bank. Three outputs come off a single footprint: destroyed organics, recovered regenerated salt suitable for industrial reuse, and process-grade steam that offsets natural gas consumption elsewhere on site.<\/p>\n<p style=\"font-size: 16px; line-height: 1.75; color: #1a2a3a; margin: 0 0 24px 0;\">For Australian operators running reverse osmosis, evaporators or crystallisers that already concentrate process wastewater, this unit finishes the job. It turns the stubborn 5\u201335% TDS reject stream into something auditable under NSW EPA, Victoria EPA and Queensland DES licensing \u2014 and into a material line on the P&amp;L rather than a liability.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1105\" src=\"https:\/\/rtooxidizer.com\/wp-content\/uploads\/2026\/04\/high-salinity-waste-liquid-boiler.webp\" alt=\"High-Salinity Waste Liquid Incinerator\" width=\"1104\" height=\"928\" title=\"\" srcset=\"https:\/\/rtooxidizer.com\/wp-content\/uploads\/2026\/04\/high-salinity-waste-liquid-boiler.webp 1104w, https:\/\/rtooxidizer.com\/wp-content\/uploads\/2026\/04\/high-salinity-waste-liquid-boiler-980x824.webp 980w, https:\/\/rtooxidizer.com\/wp-content\/uploads\/2026\/04\/high-salinity-waste-liquid-boiler-480x403.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1104px, 100vw\" \/><!-- =============== FEED STREAMS IT HANDLES =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Waste Liquids This Boiler Can Process<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(260px,1fr)); gap: 18px; margin: 0 0 30px 0;\">\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">RO \/ Membrane Reject<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Reverse osmosis concentrate from coal-seam gas, mine dewatering, food processing and chemical desalination loops. TDS 5\u201315%.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Pharmaceutical Mother Liquor<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Sodium-salt-laden mother liquor from API crystallisation; DMF, DMSO or MeOH residues; pH 2\u201311.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Textile Dye Concentrate<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">High-colour azo-dye wash water with sodium sulfate and NaCl. Organic destruction required before salt can be reused.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Coking &amp; Coal Chemical Brine<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">High-ammonia, high-phenol, high-salt wastewater from coking, gasification and coal-to-chemical plants.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Electroplating &amp; PCB Rinse<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Metal-bearing rinse concentrates from electronics and surface-finishing lines; sulfate- and chloride-heavy.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Landfill Leachate Concentrate<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Post-evaporator leachate concentrate with persistent organics. Dry-salt discharge removes a contentious liability.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== HOW IT WORKS =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">How the High-Salinity Waste Liquid Incinerator Works<\/h2>\n<p style=\"font-size: 16px; line-height: 1.75; color: #1a2a3a; margin: 0 0 22px 0;\">Five engineered stages take concentrated brine in and deliver dry salt, clean flue gas and useful steam out. The process is controlled as a single unit through one PLC \u2014 no operator juggling multiple skids.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(250px,1fr)); gap: 18px; margin: 0 0 30px 0;\">\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 01<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Feed Conditioning<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Brine is filtered, heated and pressurised to ~6 bar. A twin-fluid atomiser with steam or compressed air breaks the liquid into fine droplets.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 02<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Primary Furnace Combustion<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">A natural-gas or diesel pilot burner sustains 1,000\u20131,100 \u00b0C. Organic matter is oxidised; water evaporates; salt transforms to dry particulate or molten film.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 03<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Salt Separation<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Depending on operating mode, salt is captured as (a) dry ash from an inertial separator, or (b) molten slag tapped from a water-cooled hearth for sale as regenerated feedstock.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 04<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Steam Generation<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Hot flue gas passes through a convective boiler bank and economiser, yielding 1.5\u20138 t of saturated steam per tonne of waste liquid processed.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 05<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Flue Gas Polishing<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Bag filter, dry sorbent (Ca(OH)\u2082 or NaHCO\u2083), and optional SCR remove HCl, SOx, NOx and fine particulate to Australian licence limits.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== KEY FEATURES =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Key Features &amp; Engineering Advantages<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(260px,1fr)); gap: 18px; margin: 0 0 30px 0;\">\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Integrated Furnace + Boiler<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">One Class A licensed vessel handles combustion and heat recovery. No third-party tie-ins, no stranded pressure-part approvals.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Anti-Fouling Geometry<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Gas velocity and tube spacing are engineered to prevent alkali-salt deposition on heat transfer surfaces. Online rapping keeps efficiency within spec.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Dual Salt Discharge Mode<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Switchable between dry-salt drop-out (process reuse) and molten slag tap (disposal or vitrification). One asset, two commercial plays.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">High-Alloy Hot Path<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Inconel 625, Hastelloy C276 and SiC refractory options cover aggressive Cl\/S chemistries that would eat carbon steel within a year.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Zero Liquid Discharge Ready<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Directly replaces or complements evaporator-crystalliser trains in ZLD schemes. Works as a <em>replacement of MVR crystalliser<\/em> where organics defeat thermal concentration.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Auto Load Control<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">PLC trims auxiliary fuel, atomising media and excess air as brine calorific value swings across the shift. No operator intervention required.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== TECHNICAL SPECS =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Technical Specifications<\/h2>\n<p style=\"font-size: 15px; line-height: 1.7; color: #4a5a6a; margin: 0 0 18px 0;\">Standard capacity bands cover most Australian brine-disposal duties. Every project is ultimately sized to the actual TDS curve, organic load and downstream steam demand of your site.<\/p>\n<div style=\"overflow-x: auto; border: 1px solid #D6E2EE; border-radius: 6px; margin: 0 0 28px 0;\">\n<table style=\"width: 100%; border-collapse: collapse; min-width: 720px; font-size: 14px;\">\n<thead>\n<tr style=\"background: #0A3A6B; color: #ffffff;\">\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Model<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Feed Rate (t\/h)<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Max TDS<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Steam Output (t\/h)<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Aux Fuel (Nm\u00b3\/h NG)<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Salt Recovery Mode<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-HS-1<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">1<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">30%<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">2\u20133<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">55<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Dry salt<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-HS-3<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">3<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">30%<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">5\u20138<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">160<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Dry \/ molten<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-HS-6<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">6<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">35%<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">10\u201316<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">320<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Dry \/ molten<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-HS-10<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">10<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">35%<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">16\u201325<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">540<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Molten tap<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-HS-20<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">20<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">35%<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">32\u201348<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">1080<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Molten tap<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 style=\"font-size: 20px; color: #0a3a6b; margin: 28px 0 14px 0;\">Performance &amp; Compliance<\/h3>\n<div style=\"overflow-x: auto; border: 1px solid #D6E2EE; border-radius: 6px; margin: 0 0 28px 0;\">\n<table style=\"width: 100%; border-collapse: collapse; min-width: 600px; font-size: 14px;\">\n<thead>\n<tr style=\"background: #0A3A6B; color: #ffffff;\">\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Parameter<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Ever-power Guarantee<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Australian EPA Limit (typical)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Organic Destruction Efficiency<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">\u2265 99.99%<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">99.99%<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">HCl (as Cl)<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">&lt; 10 mg\/Nm\u00b3<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">60 mg\/Nm\u00b3<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">SO\u2082<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">&lt; 40 mg\/Nm\u00b3<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">200 mg\/Nm\u00b3<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">NOx (as NO\u2082)<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">&lt; 180 mg\/Nm\u00b3<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">350 mg\/Nm\u00b3<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Particulates<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">&lt; 8 mg\/Nm\u00b3<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">30 mg\/Nm\u00b3<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Recovered Salt Purity<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">&gt; 96% (typical)<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><!-- =============== APPLICATIONS =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Applications Across Australian Industry<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(240px,1fr)); gap: 16px; margin: 0 0 30px 0;\">\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Pharmaceutical &amp; Fine Chemical<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Brine-laden mother liquor from API crystallisation. Regenerated Na\u2082SO\u2084 returned to upstream reactors.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Coal-Seam Gas &amp; Mining<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Produced-water RO reject in QLD CSG fields; mine dewatering concentrate in WA iron ore and NSW coal.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Textile &amp; Dye Finishing<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Reactive-dye wash water, azo-dye intermediate brines, finishing-line discharge.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Electronics &amp; PCB<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Spent electrolyte, nickel-copper rinse, photoresist-laden wash. Metal-bearing salts trapped in ash.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Landfill &amp; Leachate<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Post-evaporator leachate concentrate; PFAS-precursor thermal destruction support with SCWO pre-stage.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Food &amp; Beverage<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Whey concentrate, fermentation blowdown, CIP waste from high-salt sauce and meat processing plants.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== WHY EVER-POWER =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Why Choose Ever-power<\/h2>\n<p style=\"font-size: 16px; line-height: 1.7; color: #1a2a3a; margin: 0 0 22px 0;\">Brine destruction is where cheap thermal oxidiser suppliers quietly walk away. Tubes foul, refractory spalls, scrubbers choke on chloride \u2014 and the warranty letter becomes a bargaining chip. These six commitments set Ever-power apart from a generic <em>replacement of imported brine incinerator<\/em> that was never engineered for your actual TDS curve.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(280px,1fr)); gap: 18px; margin: 0 0 30px 0;\">\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">80+<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">brine incinerator units in operation across pharma, coal chemical and textile sectors, each with documented 10-year reference data.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">Pilot<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">50 L\/h bench rig available in our technical centre \u2014 burn your actual brine before committing to a full-scale build.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">C276<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">Hastelloy C276 &amp; Inconel 625 tube options on-stock \u2014 no 30-week mill lead time on high-alloy retubes.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">2-year<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">pressure-part warranty plus performance guarantee on destruction efficiency and steam output, backed by acceptance testing.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">ZLD<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">complete zero-liquid-discharge scheme available \u2014 MVR crystalliser, dryer, incinerator, bag house and salt silo as a single responsibility.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">CEMS<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">continuous emissions monitoring with direct feed into NSW, VIC and QLD EPA portals \u2014 compliance reporting built in, not bolted on.<\/div>\n<\/div>\n<\/div>\n<p style=\"font-size: 15px; line-height: 1.7; color: #4a5a6a; margin: 0 0 26px 0;\">Explore our engineering facilities and test centre on the <a style=\"color: #1b6aa8; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/rtooxidizer.com\/nl\/company\/\">Ever-power company page<\/a>, or browse our full waste liquid incinerator and boiler range on our <a style=\"color: #1b6aa8; font-weight: 600; text-decoration: underline;\" href=\"\/nl\/\">home page<\/a>.<\/p>\n<p><!-- =============== CASE STUDIES =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Australian Project Case Studies<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(320px,1fr)); gap: 24px; margin: 0 0 30px 0;\">\n<div style=\"background: #F5F8FB; border-left: 5px solid #1B6AA8; padding: 26px; border-radius: 6px;\">\n<div style=\"font-size: 12px; color: #c8102e; font-weight: bold; letter-spacing: 1.5px; margin-bottom: 8px;\">CASE STUDY 01 \u2022 QUEENSLAND<\/div>\n<h3 style=\"font-size: 20px; color: #0a3a6b; margin: 0 0 12px 0;\">Coal-Seam Gas Produced-Water Facility \u2014 Surat Basin<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0 0 12px 0;\">A CSG operator was trucking 30,000 t\/year of RO reject brine to offsite disposal at A$350\/t. The site had reached its existing landfill contract limit and needed a permanent ZLD solution compliant with the Queensland underground water licence.<\/p>\n<div style=\"background: #ffffff; padding: 14px 16px; border-radius: 4px; margin: 14px 0;\">\n<p style=\"font-size: 13px; line-height: 1.6; color: #1a2a3a; margin: 0 0 6px 0;\"><strong>Ever-power solution:<\/strong> EP-HS-6 integrated furnace-boiler with dry salt recovery, bag filter and HCl scrubber. Steam feeds on-site amine regeneration.<\/p>\n<p style=\"font-size: 13px; line-height: 1.6; color: #1a2a3a; margin: 0;\"><strong>Result:<\/strong> A$8.9M\/year disposal cost eliminated. Recovered salt sold to industrial buyer at A$70\/t. Payback 32 months, zero offsite brine since commissioning.<\/p>\n<\/div>\n<\/div>\n<div style=\"background: #F5F8FB; border-left: 5px solid #1B6AA8; padding: 26px; border-radius: 6px;\">\n<div style=\"font-size: 12px; color: #c8102e; font-weight: bold; letter-spacing: 1.5px; margin-bottom: 8px;\">CASE STUDY 02 \u2022 VICTORIA<\/div>\n<h3 style=\"font-size: 20px; color: #0a3a6b; margin: 0 0 12px 0;\">Pharmaceutical API Manufacturer \u2014 Western Melbourne<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0 0 12px 0;\">A contract API producer was generating 3.5 t\/h of sulfate-laden mother liquor. Biological treatment was failing acute toxicity tests, and the site&#8217;s trade waste discharge licence was under EPA review.<\/p>\n<div style=\"background: #ffffff; padding: 14px 16px; border-radius: 4px; margin: 14px 0;\">\n<p style=\"font-size: 13px; line-height: 1.6; color: #1a2a3a; margin: 0 0 6px 0;\"><strong>Ever-power solution:<\/strong> EP-HS-3 high-salinity waste liquid incinerator with Inconel 625 radiant section, as <em>replacement of existing spray dryer<\/em>.<\/p>\n<p style=\"font-size: 13px; line-height: 1.6; color: #1a2a3a; margin: 0;\"><strong>Result:<\/strong> Acute toxicity reduced to non-detect. Trade waste discharge retained. 5 t\/h saturated steam diverted to reactor jackets, saving A$1.6M\/year in natural gas.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- =============== FAQ =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Frequently Asked Questions<\/h2>\n<div style=\"margin: 0 0 30px 0;\">\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">What TDS range can the incinerator actually handle?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Continuous operation is rated from 5% TDS up to 35% TDS. Below 5% the energy penalty from water evaporation is usually uneconomic \u2014 we recommend an MVR pre-concentrator in that range. Above 35% the feed handling becomes a slurry problem and we switch to spray-dryer-plus-boiler architecture.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Is the recovered salt actually reusable?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">For single-species feeds (e.g. sodium sulfate from a pharma crystalliser) the recovered salt routinely exceeds 96% purity and is directly recycled. For mixed feeds a post-wash stage is added to separate species. Some Australian clients sell the salt to cement or chloralkali buyers; others use it as an upstream raw material credit.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">How do you prevent the infamous boiler-tube fouling problem?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Two strategies run in parallel. Mechanical: low gas velocity, wide tube pitch, and in-service soot blowing plus occasional steam washing. Thermodynamic: flue gas is kept above the salt dew point in the convective bank, so sticky condensate never forms on tube walls. Field data from 80+ units shows heat efficiency loss under 3% between cleaning cycles.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">What about PFAS, per- and polyfluoroalkyl substances?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">A high-salinity waste liquid incinerator alone is not a certified PFAS destruction unit \u2014 fluorine chemistry requires supercritical water oxidation or a specialised plasma stage for assured destruction. Ever-power offers SCWO as a pre-stage module bolted to the brine incinerator so the thermal finishing step sees only mineral-laden water.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">What is the auxiliary fuel consumption on low-calorific waste?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">For a typical 10% TDS brine with 5% organics, auxiliary natural gas consumption is around 50\u201360 Nm\u00b3 per tonne of waste liquid. High-organic feeds (e.g. solvent-laden brines) often run auxiliary-free once the furnace is hot. Every project quotes a fuel envelope based on the exact feed composition.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Can the unit run 24\/7 or is campaign operation expected?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Standard Ever-power design is continuous 8,000+ hours per year. Offline time is used for refractory inspection, soot blower checks and scheduled bag filter changes. Campaign operation is possible for sites with seasonal brine generation \u2014 we simply engineer the refractory for additional thermal cycling.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Do you have Australian references we can visit?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Yes. Under mutual NDA, we can arrange site visits to operating Ever-power high-salinity waste liquid incinerator installations in Queensland, Victoria and NSW. Reference customer calls are organised during the tender evaluation phase.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== CTA =============== --><\/p>\n<div style=\"background: #F5F8FB; border-left: 5px solid #C8102E; padding: 24px 28px; border-radius: 6px; margin: 36px 0 20px 0;\">\n<h3 style=\"font-size: 20px; color: #0a3a6b; margin: 0 0 10px 0;\">Need a Tailored Brine Destruction Study?<\/h3>\n<p style=\"font-size: 15px; line-height: 1.7; color: #1a2a3a; margin: 0;\">Send your waste liquid analysis (TDS, COD, pH, Cl, S, metals) and steam demand to <a style=\"color: #1b6aa8; font-weight: bold; text-decoration: underline;\" href=\"mailto:sales@rtooxidizer.com\">sales@rtooxidizer.com<\/a> or reach us through the <a style=\"color: #1b6aa8; font-weight: bold; text-decoration: underline;\" href=\"https:\/\/rtooxidizer.com\/nl\/contacts\/\">contact page<\/a>. A full destruction study, salt-recovery estimate and budget price will be returned within 10 working days \u2014 free of charge.<\/p>\n<\/div>\n<p><!-- =============== STRUCTURED DATA =============== --><br \/>\n<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"Product\",\n    \"name\": \"High-Salinity Waste Liquid Boiler\",\n    \"image\": \"https:\\\/\\\/rtooxidizer.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/high-salinity-waste-liquid-boiler.webp\",\n    \"description\": \"Integrated Class A furnace-boiler for high-TDS brine. Destroys organics to >99.99%, recovers regenerated salt, produces process steam. ZLD-ready for Australian pharma, CSG and coal chemical operators.\",\n    \"brand\": {\n        \"@type\": \"Brand\",\n        \"name\": \"Ever-power\"\n    },\n    \"manufacturer\": {\n        \"@type\": \"Organization\",\n        \"name\": \"Ever-power\",\n        \"url\": \"https:\\\/\\\/rtooxidizer.com\\\/\",\n        \"email\": \"sales@rtooxidizer.com\"\n    },\n    \"category\": \"Industrial Boiler \\\/ High-Salinity Waste Liquid Incinerator\",\n    \"aggregateRating\": {\n        \"@type\": \"AggregateRating\",\n        \"ratingValue\": \"4.9\",\n        \"reviewCount\": \"31\",\n        \"bestRating\": \"5\"\n    }\n}<\/script><\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What TDS range can the incinerator actually handle?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Continuous operation is rated from 5% TDS up to 35% TDS. Below 5% the water evaporation penalty is usually uneconomic \\u2014 an MVR pre-concentrator is recommended. Above 35% the feed becomes a slurry problem and we switch to spray-dryer-plus-boiler architecture.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Is the recovered salt actually reusable?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"For single-species feeds the recovered salt routinely exceeds 96% purity and is directly recycled. For mixed feeds a post-wash stage separates species. Some Australian clients sell the salt to cement or chloralkali buyers; others use it as upstream raw-material credit.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How do you prevent the boiler-tube fouling problem?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Two strategies in parallel: mechanical \\u2014 low gas velocity, wide tube pitch, soot blowing and steam washing; thermodynamic \\u2014 flue gas kept above salt dew point in the convective bank so sticky condensate never forms on tube walls. Field data shows efficiency loss under 3% between cleaning cycles.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What about PFAS destruction?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"A high-salinity waste liquid incinerator alone is not a certified PFAS destruction unit. Ever-power offers SCWO as a pre-stage module bolted to the incinerator so the thermal finishing step sees only mineral-laden water.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is the auxiliary fuel consumption on low-calorific waste?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"For typical 10% TDS brine with 5% organics, auxiliary natural gas consumption is around 50\\u201360 Nm\\u00b3 per tonne. High-organic feeds often run auxiliary-free once the furnace is hot. Every project quotes a fuel envelope based on the exact feed composition.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can the unit run 24\\\/7?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Standard Ever-power design is continuous 8,000+ hours per year. Offline time is used for refractory inspection, soot blower checks and scheduled bag filter changes. Campaign operation is possible for seasonal brine generation.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Do you have Australian references we can visit?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. Under mutual NDA, site visits to operating Ever-power high-salinity waste liquid incinerator installations in Queensland, Victoria and NSW can be arranged. Reference customer calls are organised during the tender evaluation phase.\"\n            }\n        }\n    ]\n}<\/script><\/p>","protected":false},"excerpt":{"rendered":"<p>The Ever-power high-salinity waste liquid incinerator destroys organics to \u2265 99.99% and recovers regenerated salt from 5\u201335% TDS brine streams. The integrated Class A furnace-boiler delivers 2\u201348 t\/h of saturated steam while turning pharma, CSG, textile and coal-chemical waste concentrate into compliant dry salt for Australian zero-liquid-discharge schemes.<\/p>","protected":false},"featured_media":1109,"template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[185],"product_tag":[206,176,205,209,203,207,208],"class_list":{"0":"post-1129","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-class-a-boiler","7":"product_tag-brine-incinerator","8":"product_tag-hazardous-waste-incinerator","9":"product_tag-high-salinity-waste-liquid-incinerator","10":"product_tag-high-tds-waste-treatment","11":"product_tag-industrial-boiler-australia","12":"product_tag-salt-recovery-boiler","13":"product_tag-zld-boiler","15":"first","16":"instock","17":"shipping-taxable","18":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/rtooxidizer.com\/nl\/wp-json\/wp\/v2\/product\/1129","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rtooxidizer.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/rtooxidizer.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rtooxidizer.com\/nl\/wp-json\/wp\/v2\/media\/1109"}],"wp:attachment":[{"href":"https:\/\/rtooxidizer.com\/nl\/wp-json\/wp\/v2\/media?parent=1129"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/rtooxidizer.com\/nl\/wp-json\/wp\/v2\/product_brand?post=1129"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/rtooxidizer.com\/nl\/wp-json\/wp\/v2\/product_cat?post=1129"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/rtooxidizer.com\/nl\/wp-json\/wp\/v2\/product_tag?post=1129"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}