{"id":1132,"date":"2026-04-24T07:11:47","date_gmt":"2026-04-24T07:11:47","guid":{"rendered":"https:\/\/rtooxidizer.com\/?post_type=product&#038;p=1132"},"modified":"2026-04-24T07:11:47","modified_gmt":"2026-04-24T07:11:47","slug":"fire-tube-boiler","status":"publish","type":"product","link":"https:\/\/rtooxidizer.com\/pt\/product\/fire-tube-boiler\/","title":{"rendered":"Fire-Tube Boiler"},"content":{"rendered":"<p><!-- =============== QUICK SPEC STRIP =============== --><\/p>\n<div style=\"display: flex; flex-wrap: wrap; gap: 16px; margin: 0 0 36px 0;\">\n<div style=\"flex: 1 1 180px; background: #EEF5FC; border-left: 4px solid #1B6AA8; padding: 18px 20px; border-radius: 6px;\">\n<div style=\"font-size: 26px; font-weight: 800; color: #0a3a6b; line-height: 1;\">1\u201335 t\/h<\/div>\n<div style=\"font-size: 13px; color: #4a5a6a; margin-top: 6px;\">Steam Capacity Range<\/div>\n<\/div>\n<div style=\"flex: 1 1 180px; background: #EEF5FC; border-left: 4px solid #1B6AA8; padding: 18px 20px; border-radius: 6px;\">\n<div style=\"font-size: 26px; font-weight: 800; color: #0a3a6b; line-height: 1;\">\u2265 95%<\/div>\n<div style=\"font-size: 13px; color: #4a5a6a; margin-top: 6px;\">Thermal Efficiency (with economiser)<\/div>\n<\/div>\n<div style=\"flex: 1 1 180px; background: #EEF5FC; border-left: 4px solid #1B6AA8; padding: 18px 20px; border-radius: 6px;\">\n<div style=\"font-size: 26px; font-weight: 800; color: #0a3a6b; line-height: 1;\">3 &amp; 4 Pass<\/div>\n<div style=\"font-size: 13px; color: #4a5a6a; margin-top: 6px;\">Wet-Back Configuration<\/div>\n<\/div>\n<div style=\"flex: 1 1 180px; background: #EEF5FC; border-left: 4px solid #1B6AA8; padding: 18px 20px; border-radius: 6px;\">\n<div style=\"font-size: 26px; font-weight: 800; color: #0a3a6b; line-height: 1;\">&lt; 80 mg\/Nm\u00b3<\/div>\n<div style=\"font-size: 13px; color: #4a5a6a; margin-top: 6px;\">NOx on Natural Gas<\/div>\n<\/div>\n<\/div>\n<p><!-- =============== OVERVIEW =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 10px 0 22px 0;\">What Is an Industrial Fire-Tube Boiler?<\/h2>\n<p style=\"font-size: 16px; line-height: 1.75; color: #1a2a3a; margin: 0 0 18px 0;\">The Ever-power <strong>industrial fire-tube boiler<\/strong> is a packaged steam boiler built around a scotch-marine shell. Hot combustion gases from the burner travel through a corrugated furnace tube and then back through banks of smoke tubes, transferring heat to the water surrounding them. Steam forms in the upper half of the shell and is drawn off through a steam drum at saturation pressure.<\/p>\n<p style=\"font-size: 16px; line-height: 1.75; color: #1a2a3a; margin: 0 0 18px 0;\">This is the most proven steam-boiler architecture in world industry \u2014 the Australian food, textile, pharmaceutical, hospital, hotel and chemical sectors have used versions of it for over a century. Ever-power builds the modern wet-back three-pass and four-pass variants with full AS\/NZS 3788 inspection documentation, low-NOx burner trains and optional stack economiser that pushes thermal efficiency above 95%.<\/p>\n<p style=\"font-size: 16px; line-height: 1.75; color: #1a2a3a; margin: 0 0 24px 0;\">Compared with a water-tube boiler at the same capacity, a fire-tube unit offers a compact footprint, simple operation, lower capital cost and easier day-to-day maintenance. It is the standard choice up to about 25 t\/h and is available as a dual-fuel unit running natural gas, LPG, diesel or light fuel oil \u2014 with an optional waste liquid incinerator tie-in where a chemical plant wants to co-fire process off-gas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1103\" src=\"https:\/\/rtooxidizer.com\/wp-content\/uploads\/2026\/04\/fire-tube-boiler.webp\" alt=\"Fire-Tube Boiler\" width=\"1216\" height=\"848\" title=\"\" srcset=\"https:\/\/rtooxidizer.com\/wp-content\/uploads\/2026\/04\/fire-tube-boiler.webp 1216w, https:\/\/rtooxidizer.com\/wp-content\/uploads\/2026\/04\/fire-tube-boiler-980x683.webp 980w, https:\/\/rtooxidizer.com\/wp-content\/uploads\/2026\/04\/fire-tube-boiler-480x335.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1216px, 100vw\" \/><!-- =============== PASS CONFIGURATIONS =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Pass Configurations &amp; Fuel Options<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(260px,1fr)); gap: 18px; margin: 0 0 30px 0;\">\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Three-Pass Wet-Back<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Standard configuration for 1\u201315 t\/h. Corrugated Morrison furnace plus two smoke-tube passes. Wet-back reversal chamber removes refractory maintenance at the rear.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Four-Pass Wet-Back<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Selected for 10\u201335 t\/h duties and for sites targeting maximum efficiency. Extra pass drops stack temperature ~25 \u00b0C lower than three-pass at the same load.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Natural Gas &amp; LPG<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Weishaupt, Riello or Limpsfield low-NOx burners matched to AGL, Origin or Jemena gas specifications. Full flame-safeguard and interrupted pilot.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Diesel &amp; Light Fuel Oil<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Air-atomising burner, oil preheater and booster pump skid for remote or backup operation \u2014 ideal for sites with unreliable gas supply.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Dual-Fuel (Gas + Oil)<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Swap-fire between primary gas and standby oil with automatic change-over. Critical for hospital, data centre and food-processing campuses.<\/p>\n<\/div>\n<div style=\"background: #F5F8FB; border-top: 4px solid #1B6AA8; padding: 24px 22px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Biogas &amp; Hydrogen-Ready<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Digester gas, landfill gas and up to 30% H\u2082 blend compatible. Hydrogen-ready burner upgrades offered for sites preparing for decarbonisation.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== HOW IT WORKS =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">How the Industrial Fire-Tube Boiler Works<\/h2>\n<p style=\"font-size: 16px; line-height: 1.75; color: #1a2a3a; margin: 0 0 22px 0;\">Combustion, heat transfer and steam separation all take place inside one horizontal pressure shell. Five operational stages define the steam cycle.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(250px,1fr)); gap: 18px; margin: 0 0 30px 0;\">\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 01<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Burner Firing<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">A modulating low-NOx burner fires into a corrugated Morrison furnace. Flame length and shape are controlled to prevent impingement on the rear tube plate.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 02<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">First Pass \u2014 Radiant Furnace<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Flue gas at 1,300\u20131,500 \u00b0C transfers radiant heat to the water through the furnace wall, cooling to about 950 \u00b0C by the reversal chamber.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 03<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Smoke Tube Passes<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Two (or three) banks of smoke tubes carry flue gas forward and back, transferring convective heat. Stack exit temperature typically 200\u2013230 \u00b0C.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 04<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Steam Separation<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Generated steam rises to the top of the shell, passes through baffle and mesh separators, and leaves via the main stop valve at \u2265 98% dryness fraction.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-left: 5px solid #C8102E; padding: 22px 20px; border-radius: 6px;\">\n<div style=\"font-size: 13px; font-weight: bold; color: #c8102e; letter-spacing: 1px; margin-bottom: 6px;\">STEP 05<\/div>\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 8px 0;\">Economiser &amp; Stack<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Optional stack economiser preheats boiler feedwater using exit flue gas \u2014 typically lifting overall efficiency from ~90% to 95%+.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== KEY FEATURES =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Key Features &amp; Engineering Advantages<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(260px,1fr)); gap: 18px; margin: 0 0 30px 0;\">\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Factory-Tested Package<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Boiler, burner, control panel and trim valves are skid-assembled, hydro-tested and fire-tested in the factory \u2014 not a collection of parts to assemble on site.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Corrugated Morrison Furnace<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Wave-form furnace tube absorbs thermal expansion and keeps the pressure shell free from cyclic-fatigue cracks \u2014 the classic failure mode on flat furnace boilers.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Low-NOx Burner Standard<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Staged combustion burners deliver &lt; 80 mg\/Nm\u00b3 NOx on natural gas without flue gas recirculation \u2014 a clean <em>replacement of legacy Weishaupt-era burners<\/em>.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Modulating Control 5:1 to 10:1<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Infinite modulation across a wide turn-down range holds steam pressure tight on swinging process demand \u2014 ideal for batch food, textile and pharma sites.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Trim &amp; Safety Package<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Two independent low-water cut-offs, AS3814-compliant safety valves, TDS probe, blowdown valve set, and alarm horn \u2014 no kit to source separately.<\/p>\n<\/div>\n<div style=\"background: #EEF5FC; padding: 22px 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Remote Monitoring<\/h3>\n<p style=\"font-size: 14px; line-height: 1.65; color: #4a5a6a; margin: 0;\">Siemens or Rockwell PLC + HMI with optional VPN link to Ever-power engineers. Early alerts on flame instability, condensate losses, and tube fouling.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== TECHNICAL SPECS =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Technical Specifications<\/h2>\n<p style=\"font-size: 15px; line-height: 1.7; color: #4a5a6a; margin: 0 0 18px 0;\">Standard packages cover 1\u201335 t\/h on saturated steam from 0.8 MPa to 2.5 MPa. Higher pressures and superheated duty are available on request \u2014 fire-tube boilers above 35 t\/h are less common and water-tube boilers usually serve that segment better.<\/p>\n<div style=\"overflow-x: auto; border: 1px solid #D6E2EE; border-radius: 6px; margin: 0 0 28px 0;\">\n<table style=\"width: 100%; border-collapse: collapse; min-width: 720px; font-size: 14px;\">\n<thead>\n<tr style=\"background: #0A3A6B; color: #ffffff;\">\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Model<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Steam Output (t\/h)<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Pressure (MPa)<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Passes<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Footprint (L \u00d7 W \u00d7 H) m<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Efficiency*<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-FT-1<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">1<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">0.8 \/ 1.0<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">3-pass<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">3.8 \u00d7 1.6 \u00d7 2.0<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">\u2265 93%<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-FT-4<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">4<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">1.25 \/ 1.6<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">3-pass<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">5.1 \u00d7 2.2 \u00d7 2.5<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">\u2265 94%<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-FT-10<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">10<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">1.25 \/ 1.6 \/ 2.5<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">3 or 4-pass<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">6.8 \u00d7 2.8 \u00d7 3.1<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">\u2265 95%<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-FT-20<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">20<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">1.6 \/ 2.5<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">4-pass<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">8.5 \u00d7 3.2 \u00d7 3.6<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">\u2265 95%<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\"><strong>EP-FT-35<\/strong><\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">35<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">2.5<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">4-pass<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">11.2 \u00d7 3.8 \u00d7 4.2<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">\u2265 95%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"font-size: 12px; color: #4a5a6a; padding: 10px 14px; margin: 0; background: #F5F8FB;\">*Thermal efficiency with optional stack economiser on natural gas firing at 100% MCR.<\/p>\n<\/div>\n<h3 style=\"font-size: 20px; color: #0a3a6b; margin: 28px 0 14px 0;\">Emissions &amp; Compliance<\/h3>\n<div style=\"overflow-x: auto; border: 1px solid #D6E2EE; border-radius: 6px; margin: 0 0 28px 0;\">\n<table style=\"width: 100%; border-collapse: collapse; min-width: 600px; font-size: 14px;\">\n<thead>\n<tr style=\"background: #0A3A6B; color: #ffffff;\">\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Parameter<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Ever-power (natural gas)<\/th>\n<th style=\"padding: 14px 12px; text-align: left; color: #ffffff; border: 1px solid #0A3A6B;\">Reference Standard<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">NOx<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">&lt; 80 mg\/Nm\u00b3<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">NSW POEO 350 mg\/Nm\u00b3<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">CO<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">&lt; 40 mg\/Nm\u00b3<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">125 mg\/Nm\u00b3<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Particulates<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">&lt; 5 mg\/Nm\u00b3<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">30 mg\/Nm\u00b3<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Pressure Code<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">ASME Section I + U stamp<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">AS\/NZS 3788<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Noise @ 1 m<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">\u2264 82 dB(A)<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">AS 1055<\/td>\n<\/tr>\n<tr style=\"background: #F5F8FB;\">\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Safety Interlocks<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">Dual LWCO + flame safeguard<\/td>\n<td style=\"padding: 12px; border: 1px solid #E0E8F0;\">AS 3814 \/ AS 2593<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><!-- =============== APPLICATIONS =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Applications Across Australian Industry<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(240px,1fr)); gap: 16px; margin: 0 0 30px 0;\">\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Food &amp; Beverage<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Dairy processing, meat rendering, beer brewing, UHT lines, retort sterilisation. Swinging batch loads handled on modulating control.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Textile &amp; Laundry<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Dye house, finishing line, commercial laundry, carpet manufacture. Typically 4\u201310 t\/h duty in Australian operators.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Pharmaceutical &amp; Healthcare<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">GMP reactor heating, autoclave supply, hospital sterilisation. Clean-steam package available as a secondary loop.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Campus &amp; Hospitality<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">University, hospital and hotel steam utilities; N+1 redundancy for mission-critical services.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Chemical &amp; Light Industrial<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Resin, adhesive, paint and coatings manufacturing. Optional co-firing with waste liquid incinerator off-gas.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; padding: 20px; border-radius: 6px;\">\n<h3 style=\"font-size: 16px; color: #0a3a6b; margin: 0 0 8px 0;\">Building Materials &amp; Timber<\/h3>\n<p style=\"font-size: 13px; line-height: 1.6; color: #4a5a6a; margin: 0;\">Plasterboard, fibre cement, timber kilns and pressure treatment; steam plants sized 3\u201320 t\/h.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== WHY EVER-POWER =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Why Choose Ever-power<\/h2>\n<p style=\"font-size: 16px; line-height: 1.7; color: #1a2a3a; margin: 0 0 22px 0;\">Fire-tube boilers look like a commodity until you need one that actually hits its nameplate efficiency, passes AS\/NZS 3788 first time, and keeps running through a six-year warranty cycle. Six engineering commitments set Ever-power apart from a generic <em>replacement of imported packaged boiler<\/em>.<\/p>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(280px,1fr)); gap: 18px; margin: 0 0 30px 0;\">\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">2,000+<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">packaged fire-tube boilers shipped globally \u2014 one of the highest volume products in the Ever-power catalogue.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">95%+<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">guaranteed thermal efficiency on natural gas with stack economiser \u2014 independently verified at acceptance testing.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">3-yr<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">pressure-part warranty (industry standard is 18\u201324 months) and 12-month burner train warranty as a package.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">14 wk<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">lead time on standard EP-FT-4 to EP-FT-10 models; rush-build option available for critical-gap replacements.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">Plug<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">plug-and-play package \u2014 arrive on-site with burner fitted, panel wired, trim valved. Site-ready commissioning in 7\u201310 days.<\/div>\n<\/div>\n<div style=\"background: linear-gradient(135deg,#0A3A6B 0%,#1B6AA8 100%); color: #ffffff; padding: 24px 22px; border-radius: 6px;\">\n<div style=\"font-size: 28px; font-weight: 800; color: #ffffff; margin-bottom: 6px;\">H\u2082<\/div>\n<div style=\"font-size: 14px; line-height: 1.6; color: #d6e6f5;\">hydrogen-ready burner option for sites on a 2030\u20132035 decarbonisation pathway. Future-proof the pressure vessel now.<\/div>\n<\/div>\n<\/div>\n<p style=\"font-size: 15px; line-height: 1.7; color: #4a5a6a; margin: 0 0 26px 0;\">More on our factory certification and QA process is on the <a style=\"color: #1b6aa8; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/rtooxidizer.com\/pt\/company\/\">Ever-power company page<\/a>, or see the full boiler and waste liquid incinerator catalogue on our <a style=\"color: #1b6aa8; font-weight: 600; text-decoration: underline;\" href=\"\/pt\/\">home page<\/a>.<\/p>\n<p><!-- =============== CASE STUDIES =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Australian Project Case Studies<\/h2>\n<div style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(320px,1fr)); gap: 24px; margin: 0 0 30px 0;\">\n<div style=\"background: #F5F8FB; border-left: 5px solid #1B6AA8; padding: 26px; border-radius: 6px;\">\n<div style=\"font-size: 12px; color: #c8102e; font-weight: bold; letter-spacing: 1.5px; margin-bottom: 8px;\">CASE STUDY 01 \u2022 VICTORIA<\/div>\n<h3 style=\"font-size: 20px; color: #0a3a6b; margin: 0 0 12px 0;\">Dairy Processing Plant \u2014 Greater Bendigo<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0 0 12px 0;\">A mid-size dairy was running two 30-year-old package boilers at 68% average efficiency. Insurance audit flagged the safety valves and a scheduled shutdown had been pencilled in for six months later.<\/p>\n<div style=\"background: #ffffff; padding: 14px 16px; border-radius: 4px; margin: 14px 0;\">\n<p style=\"font-size: 13px; line-height: 1.6; color: #1a2a3a; margin: 0 0 6px 0;\"><strong>Ever-power solution:<\/strong> Two EP-FT-10 four-pass wet-back fire-tube boilers with low-NOx gas burners, stack economisers and shared deaerator \/ feedwater skid.<\/p>\n<p style=\"font-size: 13px; line-height: 1.6; color: #1a2a3a; margin: 0;\"><strong>Result:<\/strong> Natural gas consumption cut 32%, annual saving A$640k. Commissioning completed inside the planned 21-day shutdown, full AS\/NZS 3788 inspection first-time-pass.<\/p>\n<\/div>\n<\/div>\n<div style=\"background: #F5F8FB; border-left: 5px solid #1B6AA8; padding: 26px; border-radius: 6px;\">\n<div style=\"font-size: 12px; color: #c8102e; font-weight: bold; letter-spacing: 1.5px; margin-bottom: 8px;\">CASE STUDY 02 \u2022 QUEENSLAND<\/div>\n<h3 style=\"font-size: 20px; color: #0a3a6b; margin: 0 0 12px 0;\">University Campus \u2014 Brisbane<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0 0 12px 0;\">A campus steam utility needed to replace one of three N+1 redundant boilers with a higher-efficiency unit while maintaining 24\/7 supply to medical, research and catering facilities.<\/p>\n<div style=\"background: #ffffff; padding: 14px 16px; border-radius: 4px; margin: 14px 0;\">\n<p style=\"font-size: 13px; line-height: 1.6; color: #1a2a3a; margin: 0 0 6px 0;\"><strong>Ever-power solution:<\/strong> EP-FT-4 three-pass dual-fuel (gas + diesel) fire-tube boiler with remote-monitoring VPN link, as a direct <em>replacement of end-of-life unit<\/em>.<\/p>\n<p style=\"font-size: 13px; line-height: 1.6; color: #1a2a3a; margin: 0;\"><strong>Result:<\/strong> Campus steam supply uninterrupted across the change-out. First-year efficiency measured at 95.2% on natural gas.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- =============== FAQ =============== --><\/p>\n<h2 style=\"font-size: 28px; color: #0a3a6b; border-bottom: 3px solid #C8102E; padding-bottom: 10px; margin: 36px 0 22px 0;\">Frequently Asked Questions<\/h2>\n<div style=\"margin: 0 0 30px 0;\">\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Fire-tube versus water-tube \u2014 which is right for my site?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Fire-tube wins on simplicity, capital cost and footprint up to about 25 t\/h at pressures under 2.5 MPa. Water-tube wins above that capacity, for superheated steam above 350 \u00b0C, and where rapid load swing and high cycle count matter. For typical Australian food, textile, pharma, hospital and campus duty, fire-tube is the natural fit.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Three-pass or four-pass \u2014 what&#8217;s the real difference?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Four-pass drops the stack exit temperature by roughly 25 \u00b0C at the same load, which adds about 1\u20131.5 percentage points of efficiency. In return the shell is slightly longer and flue gas pressure drop is higher. On gas prices above A$12\/GJ, four-pass usually pays back the modest capital uplift inside two years.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">What water quality does the boiler need?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Boiler feedwater should meet AS 3814 for shell boilers above 0.35 MPa: conductivity under 3,500 \u00b5S\/cm, TDS under 3,500 mg\/L, hardness under 5 mg\/L as CaCO\u2083, oxygen under 0.02 mg\/L, pH 8.5\u201310.5. A reverse-osmosis or softener + deaerator package is usually supplied with the boiler to hold those numbers.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Can I run the boiler on biogas or a hydrogen blend?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Biogas is straightforward \u2014 we have reference sites on digester gas with scrubbing and a siloxane guard. Hydrogen blends up to 30% are feasible on most low-NOx burners with minor valve-train modifications; 100% hydrogen requires a dedicated H\u2082 burner and updated flame safeguard logic, which is available as a future-retrofit kit.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">What operator class is required to run this boiler in Australia?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">The boiler licence class depends on the state and the heating surface or steam output. Most jurisdictions require a Standard Boiler Operator certificate for shell boilers up to 25 t\/h saturated at 2.5 MPa. High-hazard licences apply above that threshold. We provide licensing guidance and training material with every handover.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">How often does the boiler need inspection and internal cleaning?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">AS\/NZS 3788 typically calls for an external inspection every 12 months and an internal inspection every 24 months for low-risk plant. Internal fire-side cleaning is usually a 12-month task on urban gas sites and every 6 months on dusty industrial sites. Automatic soot-blower retrofits are available for dusty duty.<\/p>\n<\/div>\n<div style=\"background: #ffffff; border: 1px solid #D6E2EE; border-radius: 6px; padding: 22px 24px; margin-bottom: 14px;\">\n<h3 style=\"font-size: 17px; color: #0a3a6b; margin: 0 0 10px 0;\">Do you support existing boilers not supplied by Ever-power?<\/h3>\n<p style=\"font-size: 14px; line-height: 1.7; color: #4a5a6a; margin: 0;\">Yes. We carry out retubing, refractory replacement, burner upgrade and control-panel retrofit on most shell boilers from major Australian and imported brands. A condition survey is the first step and typically takes one site day plus a report.<\/p>\n<\/div>\n<\/div>\n<p><!-- =============== CTA =============== --><\/p>\n<div style=\"background: #F5F8FB; border-left: 5px solid #C8102E; padding: 24px 28px; border-radius: 6px; margin: 36px 0 20px 0;\">\n<h3 style=\"font-size: 20px; color: #0a3a6b; margin: 0 0 10px 0;\">Need a Fire-Tube Boiler Sized for Your Plant?<\/h3>\n<p style=\"font-size: 15px; line-height: 1.7; color: #1a2a3a; margin: 0;\">Send your steam demand curve, fuel type and site details to <a style=\"color: #1b6aa8; font-weight: bold; text-decoration: underline;\" href=\"mailto:sales@rtooxidizer.com\">sales@rtooxidizer.com<\/a> or use the <a style=\"color: #1b6aa8; font-weight: bold; text-decoration: underline;\" href=\"https:\/\/rtooxidizer.com\/pt\/contacts\/\">contact page<\/a>. A full sizing, GA drawing and budget price will be returned within 10 working days \u2014 free of charge.<\/p>\n<\/div>\n<p><!-- =============== STRUCTURED DATA =============== --><br \/>\n<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"Product\",\n    \"name\": \"Industrial Fire-Tube Boiler\",\n    \"image\": \"https:\\\/\\\/rtooxidizer.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/fire-tube-boiler.webp\",\n    \"description\": \"Class A packaged industrial fire-tube boiler \\u2014 three-pass and four-pass wet-back scotch-marine design. 1\\u201335 t\\\/h steam, \\u226595% efficiency, AS\\\/NZS 3788 compliant for Australian food, textile, pharma, hospital and campus use.\",\n    \"brand\": {\n        \"@type\": \"Brand\",\n        \"name\": \"Ever-power\"\n    },\n    \"manufacturer\": {\n        \"@type\": \"Organization\",\n        \"name\": \"Ever-power\",\n        \"url\": \"https:\\\/\\\/rtooxidizer.com\\\/\",\n        \"email\": \"sales@rtooxidizer.com\"\n    },\n    \"category\": \"Industrial Boiler \\\/ Fire-Tube Steam Boiler\",\n    \"aggregateRating\": {\n        \"@type\": \"AggregateRating\",\n        \"ratingValue\": \"4.9\",\n        \"reviewCount\": \"85\",\n        \"bestRating\": \"5\"\n    }\n}<\/script><\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Fire-tube versus water-tube \\u2014 which is right for my site?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Fire-tube wins on simplicity, capital cost and footprint up to about 25 t\\\/h at pressures under 2.5 MPa. Water-tube wins above that capacity, for superheated steam above 350 \\u00b0C, and where rapid load swing and high cycle count matter. For typical Australian food, textile, pharma, hospital and campus duty, fire-tube is the natural fit.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Three-pass or four-pass \\u2014 what is the real difference?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Four-pass drops stack exit temperature by roughly 25 \\u00b0C at the same load, adding about 1\\u20131.5 percentage points of efficiency. In return the shell is slightly longer and flue gas pressure drop is higher. At gas prices above A$12\\\/GJ, four-pass usually pays back the modest capital uplift inside two years.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What water quality does the boiler need?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Boiler feedwater should meet AS 3814 for shell boilers above 0.35 MPa: conductivity under 3,500 \\u00b5S\\\/cm, TDS under 3,500 mg\\\/L, hardness under 5 mg\\\/L as CaCO\\u2083, oxygen under 0.02 mg\\\/L, pH 8.5\\u201310.5. A reverse-osmosis or softener plus deaerator package is usually supplied with the boiler.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can I run the boiler on biogas or a hydrogen blend?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Biogas is straightforward, with reference sites on digester gas using scrubbing and a siloxane guard. Hydrogen blends up to 30% are feasible on most low-NOx burners with minor valve-train modifications; 100% hydrogen requires a dedicated H\\u2082 burner and updated flame safeguard logic, available as a future-retrofit kit.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What operator class is required to run this boiler in Australia?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The licence class depends on state and heating surface or steam output. Most jurisdictions require a Standard Boiler Operator certificate for shell boilers up to 25 t\\\/h saturated at 2.5 MPa. High-hazard licences apply above that threshold. Licensing guidance and training material are included with every handover.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How often does the boiler need inspection and internal cleaning?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"AS\\\/NZS 3788 typically calls for external inspection every 12 months and internal inspection every 24 months for low-risk plant. Internal fire-side cleaning is usually a 12-month task on urban gas sites and every 6 months on dusty industrial sites.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Do you support existing boilers not supplied by Ever-power?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. Retubing, refractory replacement, burner upgrade and control-panel retrofit are carried out on most shell boilers from major Australian and imported brands. A condition survey is the first step and typically takes one site day plus a report.\"\n            }\n        }\n    ]\n}<\/script><\/p>","protected":false},"excerpt":{"rendered":"<p>The Ever-power industrial fire-tube boiler delivers 1\u201335 t\/h saturated steam at \u2265 95% efficiency using a three-pass or four-pass wet-back scotch-marine design. Factory-packaged with low-NOx burner, modulating control and full AS\/NZS 3788 inspection dossier \u2014 ideal for Australian food, textile, pharma, hospital, campus and light industrial steam duty.<\/p>","protected":false},"featured_media":1108,"template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[185],"product_tag":[236,231,235,214,232,233,234],"class_list":{"0":"post-1132","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-class-a-boiler","7":"product_tag-fire-tube-boiler-australia","8":"product_tag-fire-tube-boiler","9":"product_tag-four-pass-boiler","10":"product_tag-industrial-steam-boiler","11":"product_tag-packaged-steam-boiler","12":"product_tag-scotch-marine-boiler","13":"product_tag-three-pass-boiler","15":"first","16":"instock","17":"shipping-taxable","18":"product-type-simple"},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/rtooxidizer.com\/pt\/wp-json\/wp\/v2\/product\/1132","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rtooxidizer.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/rtooxidizer.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rtooxidizer.com\/pt\/wp-json\/wp\/v2\/media\/1108"}],"wp:attachment":[{"href":"https:\/\/rtooxidizer.com\/pt\/wp-json\/wp\/v2\/media?parent=1132"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/rtooxidizer.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1132"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/rtooxidizer.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1132"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/rtooxidizer.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1132"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}